skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Ibrahim, Mahmoud"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. null (Ed.)
  2. null (Ed.)
  3. null (Ed.)
  4. During the lifespan of a data center, power outages and blower cooling failures are common occurrences. Given that data centers have a vital role in modern life, it is especially important to understand these failures and their effects. A previous study [16] showed that cold aisle containment might have a negative impact on IT equipment uptime during a blower failure. This new study further analyzed the impact of containment on IT equipment uptime during a CRAH blower failure. It also compared the IT equipment performance both with and without a pressure relief mechanism implemented in the containment system. The results show that the effect of implementing pressure relief in containment solution on the IT equipment performance and response could vary and depend on the server's airflow, generation and hence types of servers deployed in cold aisle enclosure. The results also showed that when compared to the discrete sensors, the IPMI inlet temperature sensors underestimate the Ride Through Time (RTT) by 32%. This means that the RTT calculations based on the IPMI inlet sensors may be inaccurate due to variations in the sensor readings; as they exist today; in these servers. as discussed in a previous study [26]. Additionally, it was shown that all Dell PowerEdge 2950 servers have a similar IPMI inlet temperature reading, regardless of mounting location. As external system resistance increases during cooling failure, the servers exhibit internal recirculation through their weaker power supply fans, which is reflected in the high IPMI inlet temperature readings. For this server specifically, a pressure relief mechanism reduces the external resistance, thereby eliminating internal recirculation and resulting in lower IPMI inlet temperature readings. This in turn translates to a lower RTT. However, pressure relief showed conflicting results where the discrete sensors showed an increase in inlet temperature when pressure relief was introduced, thereby reducing the RTT. The CPU temperatures conformed with the discrete sensor data, indicating that containment helped increase the RTT of the servers during failure. 
    more » « less